• Login
    View Item 
    •   DSpace Home
    • ADU Repository
    • Engineering
    • Mechanical Engineering
    • View Item
    •   DSpace Home
    • ADU Repository
    • Engineering
    • Mechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Influence of bolted-joint slippage on the response of transmission towers subjected to frost-heave

    Thumbnail
    View/Open
    Influence (303.2Kb)
    Date
    2009-02
    Type
    Article
    Author
    Rajapakse, R.K.N.D.
    Gadala , Mohamed , S
    Metadata
    Show full item record
    Abstract
    Slippage of bolted joints is an important factor in the behavior of transmission towers. Field inspections of towers located in the northern regions of Canada show substantial frost-heave induced displacements. The conventional structural analysis software solutions for tower leg axial forces, based on idealized joint behavior under field-observed frost-heave induced displacements, are excessively large, implying tower failure in some cases. However, field inspections show structurally stable towers, and design engineers often consider joint slippage as the main reason for this discrepancy. In this paper, the experimental slippage behavior of transmission-tower bolted joints investigated by Ungkurupanian (2000) is incorporated into a non-linear joint finite element and applied to study the behavior of transmission towers under working loads by using the finite element method. The analysis shows that tower-leg joint slippage has a significant influence on tower behavior by either reducing the load carrying capacity or significantly increasing the deflections under working loads. On the other hand, joint slippage has a positive effect on towers subjected to frost-heave induced displacements, as the resulting member axial forces are much lower than those corresponding to rigid joints.
    URI
    https://dspace.adu.ac.ae/handle/1/1988
    DOI
    https://doi.org/10.1260%2F136943309787522641
    Citation
    Ahmed, K. I. E., Rajapakse, R. K. N. D., & Gadala, M. S. (2009). Influence of bolted-joint slippage on the response of transmission towers subjected to frost-heave. Advances in Structural Engineering, 12(1), 1-17.
    Collections
    • Mechanical Engineering

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV